Octopus 2 lumen 2 x 3 cm met 2 Bionectors en 2 ARV
Octopus is a polyurethane, transparent, supple multi-lumen extension tube for IV catheters (peripheral or central venous).
To identify the different infusion lines, each line has a hub or a clamp of a different colour.
Code 841.232 is a double lumen extension tube with 2 non-return valves, 2 Bionector and 2 clamps (green).
Length of tubes : 3 cm / 3 cm.
Code 841.24 is a double lumen extension tube with 2 Bionector and 2 clamps (white).
Length of tubes : 10 cm / 6 cm.
Code 841.25 is a double lumen extension tube with 1 Bionector and 2 clamps (white).
Length of tubes : 10 cm / 6 cm.
Code 841.26 is a double lumen extension tube with 2 Bionector and 2 clamps (white).
Length of tubes : 6 cm / 6 cm.
Code 841.34 is a triple lumen extension tube with 3 Bionector and 3 clamps (white).
Length of tubes : 10 cm / 8 cm / 6 cm.
Code 841.264 is a double lumen extension tube with 2 Bionector and 2 clamps (green and orange).
Length of tubes : 10 cm / 10 cm.
Code 841.364 is a triple lumen extension tube with 3 Bionector and 3 clamps (green, orange and white).
Length of tubes : 10 cm / 10 cm / 10 cm.
Used for peripheral cannula care, Octopus 2 has the following advantages:
- Eliminates the risk of access-associated needle-stick injury
- Reduces the risk of cannula movement in the vein causing mechanical vein irritation
- Negates the need to use the cannula injection port (non disinfectable), Bionector is disinfectable
- Eliminates the need to use a 3-way tap to run simultaneous compatible solutions
- Provides closed system (avoiding blood reflux) when accessing the catheter
- PUR material (no PVC, DEHP-free - no release of softeners)
Used for central venous catheter care, Octopus 3 has the following advantages:
- Provides closed, neelde-free access during syringe bolus dose administration and I.V. tubing change
- Eliminates the need to use a 3-way tap to run 2 or more simultaneous compatible solutions
- Eliminates the risk of blood spillage
- Eliminates the risk of air embolism
- PUR material (no PVC, no DEHP - no release of softeners)
To identify the different infusion lines, each line has a hub or a clamp of a different colour.
Code 841.232 is a double lumen extension tube with 2 non-return valves, 2 Bionector and 2 clamps (green).
Length of tubes : 3 cm / 3 cm.
Code 841.24 is a double lumen extension tube with 2 Bionector and 2 clamps (white).
Length of tubes : 10 cm / 6 cm.
Code 841.25 is a double lumen extension tube with 1 Bionector and 2 clamps (white).
Length of tubes : 10 cm / 6 cm.
Code 841.26 is a double lumen extension tube with 2 Bionector and 2 clamps (white).
Length of tubes : 6 cm / 6 cm.
Code 841.34 is a triple lumen extension tube with 3 Bionector and 3 clamps (white).
Length of tubes : 10 cm / 8 cm / 6 cm.
Code 841.264 is a double lumen extension tube with 2 Bionector and 2 clamps (green and orange).
Length of tubes : 10 cm / 10 cm.
Code 841.364 is a triple lumen extension tube with 3 Bionector and 3 clamps (green, orange and white).
Length of tubes : 10 cm / 10 cm / 10 cm.
Used for peripheral cannula care, Octopus 2 has the following advantages:
- Eliminates the risk of access-associated needle-stick injury
- Reduces the risk of cannula movement in the vein causing mechanical vein irritation
- Negates the need to use the cannula injection port (non disinfectable), Bionector is disinfectable
- Eliminates the need to use a 3-way tap to run simultaneous compatible solutions
- Provides closed system (avoiding blood reflux) when accessing the catheter
- PUR material (no PVC, DEHP-free - no release of softeners)
Used for central venous catheter care, Octopus 3 has the following advantages:
- Provides closed, neelde-free access during syringe bolus dose administration and I.V. tubing change
- Eliminates the need to use a 3-way tap to run 2 or more simultaneous compatible solutions
- Eliminates the risk of blood spillage
- Eliminates the risk of air embolism
- PUR material (no PVC, no DEHP - no release of softeners)
Code |
Extension tube
Total priming volume ml |
Voie 1
Flowrate ml/min |
Voie 1
Length cm |
Voie 1
Internal diameter mm |
Voie 1
External diameter mm |
Voie 1
Priming volume ml |
Voie 2
Flowrate ml/min |
Voie 2
Length cm |
Voie 2
Internal diameter mm |
Voie 2
External diameter mm |
Voie 2
Priming volume ml |
---|---|---|---|---|---|---|---|---|---|---|---|
841.232 | 0.50 | 78 | 3 | 1.50 | 2.50 | 0.30 | 78 | 3 | 1.50 | 2.50 | 0.30 |
841.264 | 0.57 | 82 | 10 | 1.50 | 2.50 | 0.34 | 82 | 10 | 1.50 | 2.50 | 0.34 |
842.209 | 0.58 | 73 | 6 | 1.50 | 2.50 | 0.36 | 78 | 6 | 1.50 | 2.50 | 0.33 |
Extension tube | Voie 1 | Voie 2 | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Total priming volume ml |
Flowrate ml/min |
Length cm |
Internal diameter mm |
External diameter mm |
Priming volume ml |
Flowrate ml/min |
Length cm |
Internal diameter mm |
External diameter mm |
Priming volume ml |
|
841.232 | 0.50 | 78 | 3 | 1.50 | 2.50 | 0.30 | 78 | 3 | 1.50 | 2.50 | 0.30 | |
841.264 | 0.57 | 82 | 10 | 1.50 | 2.50 | 0.34 | 82 | 10 | 1.50 | 2.50 | 0.34 | |
842.209 | 0.58 | 73 | 6 | 1.50 | 2.50 | 0.36 | 78 | 6 | 1.50 | 2.50 | 0.33 |
- Contains Latex: No
- Contains DEHP: No
- Contains biogical or animal-based product: No
- Non-pyrogenic: Yes