Nutriline 3Fr, 30cm met Breakaway needle 17G
3 Fr peripherally inserted central venous catheter in polyurethane for babies, infants and children (drugs administration, parenteral nutrition...).
Nutriline is inserted through a splitting introducer needle, completely removed after insertion of the catheter. The catheter features markings every centimetre and a black mark on the distal end allowing the user to check that the entire catheter has been withdrawn.
The catheter tubing is in highly thermo-sensitive polyurethane which makes catheter insertion easy, yet softens quickly after placement.
Nutriline is supplied in a rigid blister pack containing:
- 1 polyurethane catheter 15cm long (code 1253.15) or 30cm long (code 1253.30) with integral extension tube (9cm long)
- 1 splitting needle
- 1 syringe (3 ml)
- 1 measuring tape
Nutriline code 1353.302 is supplied in a supple blister pack, in a small tray wrapped into a non-woven drape and contains: 1 Nutriline catheter (3 Fr - 30 cm long), 1 peelable cannula, 1 filter straw, 1 syringe 10 ml, 1 gallipot, 1 injection cap, 1 sponge stick, 1 fenestrated adhesive drape, 2 ball swabs : see corresponding technical file.
Code |
Catheter
Int. Ø mm |
Catheter
Ext. Ø mm |
Catheter
Gauge G |
Catheter
Length cm |
Catheter
Flow rate for 1 bar pressure ml/min |
Catheter
Prim. vol. ml |
Catheter
Flow rate by gravity ml/min |
Catheter
Ø Fr |
Introducer
Length mm |
Introducer
G G |
Introducer Type |
Introducer
Ext. Ø mm |
Stylet - |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1252.030 | 0.3 | 0.6 | 24 | 30 | 5.0 | 0.12 | - | 2 | 18 | 20 | Microflash | 1.1 | Yes |
1252.15 | 0.3 | 0.6 | 24 | 15 | 9.0 | 0.06 | - | 2 | 25 | 20 | Splitting needle | 0.95 | No |
1252.150 | 0.3 | 0.6 | 24 | 15 | 9.0 | 0.06 | - | 2 | 18 | 20 | Microflash | 1.1 | No |
1252.30 | 0.3 | 0.6 | 24 | 30 | 5.0 | 0.12 | - | 2 | 25 | 20 | Splitting needle | 0.95 | No |
1252.35 | 0.3 | 0.6 | 24 | 30 | 5.0 | 0.12 | - | 2 | 18 | 20 | Microflash | 1.1 | No |
1253.15 | 0.5 | 1.0 | 20 | 15 | - | 0.09 | 5.0 | 3 | 30 | 17 | Splitting needle | 1.5 | - |
1253.30 | 0.5 | 1.0 | 20 | 30 | 20.0 | 0.16 | - | 3 | 30 | 17 | Splitting needle | 1.5 | - |
1254.30 | 0.8 | 1.3 | 18 | 30 | 90.0 | 0.42 | - | 4 | 30 | 16 | Splitting needle | 1.6 | - |
1352.152 | 0.3 | 0.6 | 24 | 15 | 9.0 | 0.06 | - | 2 | 21 | 20 | Peelable cannula | 1.0 | - |
1352.302 | 0.3 | 0.6 | 24 | 30 | 5.0 | 0.12 | - | 2 | 21 | 20 | Peelable cannula | 1.0 | - |
1353.302 | 0.5 | 1.0 | 20 | 30 | 20.0 | 0.16 | - | 3 | 45 | 17 | Peelable cannula | 1.5 | - |
Catheter | Introducer | Stylet | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Int. Ø mm |
Ext. Ø mm |
Gauge G |
Length cm |
Flow rate for 1 bar pressure ml/min |
Prim. vol. ml |
Flow rate by gravity ml/min |
Ø Fr |
Length mm |
G G |
Type | Ext. Ø mm |
- | |
1252.030 | 0.3 | 0.6 | 24 | 30 | 5.0 | 0.12 | - | 2 | 18 | 20 | Microflash | 1.1 | Yes | |
1252.15 | 0.3 | 0.6 | 24 | 15 | 9.0 | 0.06 | - | 2 | 25 | 20 | Splitting needle | 0.95 | No | |
1252.150 | 0.3 | 0.6 | 24 | 15 | 9.0 | 0.06 | - | 2 | 18 | 20 | Microflash | 1.1 | No | |
1252.30 | 0.3 | 0.6 | 24 | 30 | 5.0 | 0.12 | - | 2 | 25 | 20 | Splitting needle | 0.95 | No | |
1252.35 | 0.3 | 0.6 | 24 | 30 | 5.0 | 0.12 | - | 2 | 18 | 20 | Microflash | 1.1 | No | |
1253.15 | 0.5 | 1.0 | 20 | 15 | - | 0.09 | 5.0 | 3 | 30 | 17 | Splitting needle | 1.5 | - | |
1253.30 | 0.5 | 1.0 | 20 | 30 | 20.0 | 0.16 | - | 3 | 30 | 17 | Splitting needle | 1.5 | - | |
1254.30 | 0.8 | 1.3 | 18 | 30 | 90.0 | 0.42 | - | 4 | 30 | 16 | Splitting needle | 1.6 | - | |
1352.152 | 0.3 | 0.6 | 24 | 15 | 9.0 | 0.06 | - | 2 | 21 | 20 | Peelable cannula | 1.0 | - | |
1352.302 | 0.3 | 0.6 | 24 | 30 | 5.0 | 0.12 | - | 2 | 21 | 20 | Peelable cannula | 1.0 | - | |
1353.302 | 0.5 | 1.0 | 20 | 30 | 20.0 | 0.16 | - | 3 | 45 | 17 | Peelable cannula | 1.5 | - |
- Contains Latex: No
- Contains DEHP: No
- Contains biogical or animal-based product: No
- Non-pyrogenic: Yes